CHASSIS:
The Chassis is constructed of
IPE-140 along the long sides as girders and IPE-120 cross-beams at
the gables and IPE-120 internal cross-beams with lifting lugs. All
these steel members are welded together to give the chassis optimum
strength, rigidity and stability. All steel members are primed for
weather protection.
FLOORS:
A-SUB-FLOOR: is constructed of
steel hollow tubes joists size (30 x 60 x 1.2) mm Spaced at (400)
mm. c/c with primer coating for weather protection.
B-FLOOR DECK: is made up of (15)
mm. thick plywood boards screwed to the sub-floor joists. Marine
plywood shall be used for all wet areas.
C-FLOOR COVERING: is of (4) mm.
thick carpet except in wet areas and corridor shall be of (2) mm.
thick vinyl sheeting.
WALLS:
External Walls are constructed
of sandwich panels (50) mm. thick covered externally with (0.4) mm
pre-painted sheeting. Internally the walls are covered with
decorative plywood boards and insulated in the middle with
polystyrene (50) mm. thick.
Partitions are constructed of
insulated sandwich panels (50) mm. thick covered on both sides with
decorative plywood boards.
The wall to floor joints shall be
covered with wooden skirting.
ROOFS & CEILINGS:
Roofs are constructed of
structural steel trusses and purlins and are covered with corrugated
galvanized pre-painted roof sheets (white color).
Ceilings are covered with (6) mm.
thick decorative plywood boards and insulated with a layer of
fiberglass (50) mm. thick. The exposed face shall be finished with
texture paint and the clear height is about 240cm.from the finished
floor level.
WINDOWS
Windows are made of white
aluminum profiles of the sliding type complete with
fly-screens.
DOORS
Internal Doors are made of a
wooden frames and are covered both sides with the same decorative
plywood boards used for internal
walls.
External Doors are covered
externally with pre-painted sheeting and decorative plywood wood
boards internally.
All internal and external doors
are fitted with good quality door locks.
All doors are insulated with
Styrofoam.
ELECTRICAL
Electrical networks are executed
in accordance with approved drawings. All electrical wiring is
embedded inside the walls and ceiling. The light fixtures are of
fluorescent type or round type incandescent. Sufficient light
fittings shall be provided to have proper illumination.
Adequate no. of socket outlets,
A/C sockets and lighting switches shall be provided in each room.
All the electrical wiring shall
be connected o a Main panel Board with suitable breakers.
SANITARY
Bathrooms: Walls of bathrooms are
covered with water resistant sheets. Each bathroom is provided with:
European water closet, wash basin with mixer, mirror, shelf, soap
holder, spray hose, paper holder.
Kitchens: Walls of kitchens are
similar to bathroom walls. Each kitchen is provided with a stainless
steel sink with mixer.
All bathrooms and kitchens are
provided with suitable size of exhaust fan. The water distribution
networks shall be pressure tested in the factory after installation.
QUALITY CONTROL
Our specialized quality control
section inspects and controls the quality of all our products during
fabrication and on regular basis. MOFAB always welcomes the
customer’s inspectors to view and perform any tests deemed
necessary.
|